Industrial SMPS full electrolytic capacitor replacement

0 0 2 0 0.0

All primary and secondary electrolytic caps replaced with ESR <0.1 Ω grade; ESR measured before and after with Hioki IM3536 LCR meter; output voltage tested at 25 %, 50 %, 75 %, and 100 % load; output voltage ripple verified (peak-to-peak <50 mV); 48-hour heavy-load burn-in with efficiency calculation.

WhatsApp consultation
Estimated lead time (days)
8
Warranty (days)
90
From
$1.80
All primary and secondary electrolytic caps replaced with ESR <0.1 Ω grade; ESR measured before and after with Hioki IM3536 LCR meter; output voltage tested at 25 %,
50 %,
75 %,
and 100 % load; output voltage ripple verified (peak-to-peak <50 mV); 48-hour heavy-load burn-in with efficiency calculation.
  • MeanWell